Precision Pressure Switch

AP800

Image

AP800

Features

  • Digital LCD display, easy readout
  • Analog output:1~5V, 4~20mA
  • IP40 enclosure
  • Pressure range 0~1kPa, 0~2kPa, 0~5kPa -1~1kPa, -2~2kPa, -5~5kPa
Image

SPECIFICATIONS

Model AP801 AP811 AP802 AP812 AP805 AP815
Rated pressure range 0 ~ 1000 Pa (0 ~ 0.145 psi) -1000 ~ 1000 Pa (-0.145 ~ 0.145 psi) 0.00 ~ 2.00 kPa (0 ~ 0.29 psi) -2.00 ~ 2.00 kPa (0.29 ~ 0.29 psi) 0.0 ~ 5.00 kPa (0 ~ 0.725 psi) -5.00 ~ 5.00 kPa (-0.725 ~ 0.725 psi)
Setting pressure range -100 ~ 1000 Pa (-14.5 ~ 145 psi) -1000 ~ 1000 Pa (-145 ~ 145 psi) -0.20 ~ 2.00 kPa (-0.029 ~ 0.29 psi) -2.00 ~ 2.00 kPa (-0.29 ~ 0.29 psi) -0.50 ~ 5.00 kPa (-0.0725 ~ 0.725 psi) -5.00 ~ 5.00 kPa (-0.725 ~ 0.725 psi)
Withstand pressure
3 kPa (0.435 psi)
6 kPa (0.87 psi)
15 kPa (2.175 psi)
Fluid
Filtered air, Non-corrosive / Non-flammable gas
Set pressure resolution (Pa)
1
-
Set pressure resolution (kPa)
-
0.01
Power supply voltage
12 to 24V DC ±10%, Ripple (P-P) 10% or less
Current consumption
≤ 40mA(With no load)
Switch output
    • NPN: open collector 2 outputs
    • Max. load current: 125mA
    • Max. supply voltage: 30V DC
    • Residual voltage: ≤ 1.5V
  • PNP: open collector 2 outputs
  • Max. load current: 125mA
  • Max. supply voltage: 24V DC
  • Residual voltage: ≤ 1.5V
Repeatability
(Switch output)
±0.5% F.S. ±1 digit
Hysteresis
(Hysteresis mode)
Adjustable
Hysteresis
(Window comparator mode)
Adjustable
Response time
≤ 2.0ms (chattering-proof function: 32ms, 128ms, 1024ms selectable)
Output short circuit protection
Yes
7 segment LCD display
One color(White) (Sampling rate: 0.1 ~ 3 sec select)
Indicator accuracy
±2% F.S. ±1 digit (ambient temperature: 25 ±3°C)
Switch ON Indicator
White (1&2 lndicator) OUT1 OUT2
Analog output
(Voltage Output) (*1)
Output Voltage: 1 to 5V ±2.5% F.S. (within rated pressure range)
Linearity: ±1% F.S.
Output impedance: about 1kΩ
Analog output
(Current Output) (*2)

Output Current:
4 to 20mA ±2.5% F.S.(within rated pressure range)
Linearity: ±1% F.S.
Max.Load impedance: 250Ω at power supply of 12V 600Ω at power supply of 24V
Min.Load impedance: 50Ω

Environment
(Enclosure)
IP 40
Environment
(Ambient temp. range)
Operation: 0 ~ 50°C, Storage:-10 ~ 60°C ( No condensation or freezing)
Environment
(Ambient humidity range)
Operation/Storage: 35 ~ 85% RH ( No condensation)
Environment
(Withstand voltage)
1000V AC in 1-min (between case and lead wire)
Environment
(Insulation resistance)
50MΩ (at 500V DC, between case and lead wire)
Environment
(Vibration)
Total amplitude 1.5mm or 10G,10Hz-150Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z
Environment
(Shock)
100m/s² (10G), 3 times each in direction of X, Y and Z
Temperature
characteristic
±3% F.S. of detected pressure (25°C) at temp. Range of 0~50°C
Port size
M5
Lead wire
Oil-resistance cable(0.15mm²)
Weight
Approx. 75g (with 2 meter lead wire)