Magnetic Sensors

CS-05 - for small round type cylinders

Image

CS-05R, CS-05D, CS-05N, CS-05P

Image

SPECIFICATIONS

Type CS-05R CS-05D CS-05DE CS-05N CS-05NE CS-05P CS-05PE
Wiring Method 2-Wire type 2-Wire type 2-Wire type 3-Wire type 3-Wire type 3-Wire type 3-Wire type
Switching Logic SPST, Normally Open SPST, Normally Open SPST, Normally Open Solid State Output, Normally Open Solid State Output, Normally Open Solid State Output, Normally Open Solid State Output, Normally Open
Sensor type Reed Switch - - NPN Current Sinking NPN Current Sinking PNP Current Sourcing PNP Current Sourcing
Operating Voltage 5~240V DC/AC 10~28V DC 5~30V DC 5~30V DC 5~30V DC 5~30V DC 5~30V DC
Switching Current 100mA max. 50mA max. 200mA max. 200mA max. 200mA max. 200mA max. 200mA max.
Contact Rating (*1) 10W max. 1.5W max. 1.5W max. 6W max. 6W max. 6W max. 6W max.
Current Consumption - - - 8mA @ 24V DC max. 6mA @ 24V DC max. 8mA @ 24V DC max. 6mA @ 24V DC max.
Voltage Drop 3.5V max. 3.5V max. 3.7V max. 1V @ 200mA max. 0.5V @ 200mA max. 1V @ 200mA max. 0.5V @ 200mA max.
Leakage current - 0.8mA max. 0.1mA(40uA) max. 0.01mA max. 0.01mA max. 0.01mA max. 0.01mA max.
Indicator Red LED Red LED Red LED Red LED Red LED Green LED Green LED
Cable ø2.8, 2C, PVC ø2.8, 2C, PVC ø2.8, 2C, PVC ø2.8, 3C, PVC ø2.8, 3C, PVC ø2.8, 3C, PVC ø2.8, 3C, PVC
Operating Frequency 200Hz 1000Hz max. 1000Hz max. 1000Hz max. 1000Hz max. 1000Hz max. 1000Hz max.
Magnet Requirement (*2) 55Gauss 80Gauss 40~1000Gauss 80Gauss 40~1000Gauss 80Gauss 40~1000Gauss
Temperature Range -10~70˚C (+14~158˚F) -10~70˚C (+14~158˚F) -10~70˚C (+14~158˚F) -10~70˚C (+14~158˚F) -10~70˚C (+14~158˚F) -10~70˚C (+14~158˚F) -10~70˚C (+14~158˚F)
Shock (*3) 50G 50G 50G 50G 50G 50G 50G
Vibration (*4) 9G 9G 9G 9G 9G 9G 9G
Enclosure Classification IEC 60529 IP67 (NEMA 6) IEC 60529 IP67 (NEMA 6) IEC 60529 IP67 (NEMA 6) IEC 60529 IP67 (NEMA 6) IEC 60529 IP67 (NEMA 6) IEC 60529 IP67 (NEMA 6) IEC 60529 IP67 (NEMA 6)
Protection Circuit (*5) 1 2,4 3,4 2,3,4 3,4 2,3,4 3,4

NOTE:

  1. WARNING: Never exceed rating (Watt=Voltage x Amperage). Permanent demage to sensor will occur.
  2. Measuring standard target: ø15.5Xø8X5t (Anisotropy rubber magnet)
  3. Sin wave / X , Y , Z 3 directions / 3 times each direction / 11 ms each time.
  4. Double amplitude 1.5 mm / 10Hz~55Hz~10Hz (Sweep 1 min) / X , Y , Z 3 directions / 1 hour each time.
  5. 1=None / 2=Short-circuit / 3=Power Source Reverse polarity / 4=Surge Suppression

-